Sanyo Digital Camera VCC 5884EA User Guide

English Français Deutsch 中文简体  
INSTRUCTION MANUAL  
SPECIFICATIONS  
Scanning system  
: VCC-5995P: PAL standard 625 lines, 50 fields/sec.  
Color CCD Camera  
VCC-5884EA: NTSC standard 525 lines, 60 fields/sec.  
: 1/3" interline transfer method CCD  
: 752 (H) x 582 (V)  
Image sensor  
THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED  
SERVICE PERSON AND SHOULD CONFORM TO ALL LOCAL  
CODES.  
Number of effective pixels  
Horizontal resolution  
Minimum illumination  
Video output  
VCC-5995P  
: 540 TV lines, typical  
: 0.5 lx (F1.2, AGC ON)  
VCC-5884EA  
: 1.0 V(p-p)/75 , composite, BNC  
: More than 48 dB (AGC OFF: More than 50 dB)  
: Optical auto iris lens (DC type)/Electronic iris (indoor use)  
: CS mount  
Video S/N ratio  
Light control  
About this manual  
• Before installing and using the camera, please read this manual carefully.  
Be sure to keep it handy for later reference.  
• This manual covers two models. Any difference between the two models is indicated when  
necessary.  
Lens mount  
Flange back  
: 12.5 mm 0.5 mm/0.5 in. 0.02 in.  
: ON (Center zone metering)/OFF  
: AGC ON/OFF  
Backlight compensation  
Gain control  
Sync system  
: Internal sync/Line lock  
Operating Environment  
: Temperature: -10°C – +50°C (14°F – 122°F)  
Humidity: less than 90 % RH (no condensation)  
ATTACHING THE LENS  
Power supply  
: VCC-5995P: 24 V AC 10%, 50 Hz/ 12 – 15 V DC  
VCC-5884EA: 24 V AC 10%, 60 Hz/ 12 – 15 V DC  
To prevent damaging the camera  
Power consumption  
Weight  
: Approx. 3.6 W (with auto-iris lens)  
: Approx. 160 g/5.6 oz. (without lens)  
Dimensions  
Unit: mm (inch)  
Service  
The camera is a precision instrument. Handle it  
5 mm/0.2 in. max.  
63(2.5)  
51(2.0)  
49(1.9)  
carefully and always follow the safety precautions.  
If the camera requires service, never try to repair it  
yourself or open the casing.  
Apply adapter ring (sold separately) when you use any  
C mount lens.  
1(0.04)  
For servicing, maintenance, or repairs, consult your  
dealer or an Authorized Sanyo Service Center.  
LENS terminal for auto iris lens  
Brake coil (–)  
Drive coil (+)  
68(2.7)  
Depending on the type of the lens, the shape of the lens plug may differ.  
In this case, consult your dealer or an Authorized Sanyo Service Center.  
Brake coil (+)  
Drive coil (–)  
PRECAUTIONS  
In case of a problem  
Appearance and specifications are subject to change without prior notice or obligations.  
Protect from humidity and dust  
Do not use the unit if smoke or a strange odor comes  
from the unit, or if it seems not to function correctly. Turn  
off the power immediately and disconnect the power  
cord, and then consult your dealer or an Authorized  
Sanyo Service Center.  
To prevent damage, do not install the unit where there  
is greasy smoke or steam, where the humidity may get  
too high, or where there is a lot of dust.  
Flange-back adjustment  
1) Loosen the two screws.  
2) Set to the maximum telephoto position and focus the picture.  
1, 4  
Protect from high temperatures  
Do not install close to stoves, or other heat sources,  
such as spotlights, etc., or where it could be subject to  
direct sunlight, as this could cause deformation,  
discoloration or other damage.  
Be careful when installing close to the ceiling, in a  
kitchen or boiler room, as the temperature may rise to  
high levels.  
Do not open or modify  
2
3) Set to the maximum wide-angle position and focus the picture.  
Do not open the cabinet, as it may be dangerous and  
cause damage to the unit. For repairs, consult your  
dealer or an Authorized Sanyo Service Center.  
• When the lens barrel is turned, the CS mount ring also turns causing  
it to act as the flange-back adjustment dial.  
Repeat steps 2 and 3 until the image stays in-focus when changing from a  
wide-angle position to a telephoto position.  
Do not put objects inside the unit  
Make sure that no metal objects or flammable  
substance get inside the unit. If used with a foreign  
object inside, it could cause a fire, a short-circuit or  
damage. Be careful to protect the unit from rain, sea  
water, etc. If water or liquid gets inside the unit, turn off  
the power immediately and disconnect the power cord,  
and then consult your dealer or an Authorized Sanyo  
Service Center.  
4) Tighten the two screws.  
Cleaning  
3
• Dirt can be removed from the cabinet by wiping it with  
a soft cloth. To remove stains, wipe with a soft cloth  
moistened with a soft detergent solution and wrung  
dry, then dry by wiping with a soft cloth.  
• Do not use benzine, thinner or other chemical  
products on the cabinet, as this may cause  
deformation and paint peeling. Before using a  
chemical cloth, make sure to read all accompanying  
instructions. Make sure that no plastic or rubber  
material comes into contact with the cabinet for a  
long period of time, as this may cause damage or  
paint peeling.  
If the flange-back lock screws are loose, the CS mount ring will not be secured and it will not be possible to  
adjust the flange-back.  
Remove the lens and check that the two flange-back lock screws have been tightened, then fully install the lens  
again.  
Be careful when handling the unit  
To prevent damage, do not drop the unit or subject it to  
strong shock or vibration.  
Do not install this unit close to magnetic fields  
The magnetic fields may result in unstable operation.  
SANYO Electric Co., Ltd.  
1AC6P1P3343--  
L5CR2/XE, US (0808KP-HS)  
Printed in China  
 

Radio Shack Cordless Telephone ET 1109 User Guide
Roper Ventilation Hood RES7646J User Guide
Rose electronic Photo Scanner CTP 8S User Guide
Rotel Stereo System RT 622 User Guide
Rowenta Fan HA 425 User Guide
Samson Stereo Amplifier PB9 User Guide
Sanyo DVD Player DVD 9201 User Guide
Sanyo Microwave Oven EM C6786V User Guide
Sanyo Projector PLC XF10NL User Guide
Senco Nail Gun SCN40DW User Guide