PS250 User Instructions  
 
 
Contents  
page no.  
Safety  
Warnings  
Safe installation  
Safe use  
Cleaning the machine  
EMC compliance  
3
1
About your machine  
1.1 Description  
1.2 Display  
5
1.3 Key functions  
1.4 Error codes  
1.5 Specification  
1.6 Power supply  
2
3
Weighing  
2.1 Hold function  
10  
Setup mode  
ꢂꢃ  
3.1 Function setup  
3.2 Calibration  
12  
14  
PS250 User Instructions  
 
i
 
Declaration of Conformity  
Manufacturer  
Type  
Salter Brecknell  
PS250  
corresponds to the requirements of the following EC directives:  
EMC Directive  
EMC 89/336/EEC  
LVD 73/23/EEC  
Low Voltage Directive  
The applicable harmonised  
standards are:  
EN60950, EN50081–1,  
EN50082–1  
A copy of the original signed declaration for this instrument is available  
from:  
Salter Brecknell Weighing, P.O. Box 9533, Smethwick, West Midlands, B66 2TE  
 
 
Déclaration de Conformité  
Fabricant  
Type  
Salter Brecknell  
PS250  
Correspond aux exigences des directives CE suivantes:  
Directive CEM  
CEM 89/336/EEC  
LVD 73/23/EEC  
Directive Basse Tension  
Les standards harmonisés  
EN60950, EN500811,  
applicables sont:  
EN500821  
Une copie originale de la déclaration signée pour cet instrument est  
disponible à:  
Salter Brecknell Weighing, P.O. Box 9533, Smethwick, West Midlands, B66 2TE  
 
Konformitätserklärung  
Hersteller  
Typ  
Salter Brecknell  
PS250  
entspricht den Anforderungen der folgenden EU-Richtlinien:  
EMV-Richtlinie  
EMC 89/336/EEC  
LVD 73/23/EEC  
Niederspannungsrichtlinie  
EN60950, EN500811,  
EN500821  
Die angewendeten  
harmonisierten Normen sind:  
Eine Abschrift der original unterschriebenen Konformitätserklärung ist  
unter unten genannter Adresse erhältlich:  
Salter Brecknell Weighing, P.O. Box 9533, Smethwick, West Midlands, B66 2TE  
 
Dichiarazione di conformità  
Produttore  
Modello  
Salter Brecknell  
PS250  
è conforme alle caratteristiche previste dalle seguenti direttive CE  
Normativa EMC  
89/336/CE  
73/23/CE  
Normativa per la bassa tensione  
Le norme standard armonizzate  
applicate sono:  
EN60950, EN500811,  
EN500821  
Se richiesto, è disponibile una copia delloriginale certificato firmato da:  
Salter Brecknell Weighing, P.O. Box 9533, Smethwick, West Midlands, B66 2TE  
 
-
Electromagnetic Compatibility Statement for North America  
This equipment has been tested and found to comply with the limits for a Class A  
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to  
provide reasonable protection against harmful interference when the equipment is  
operated in a residential installation. This equipment generates, uses and can  
radiate radio frequency energy and if not installed and used in accordance with  
the instructions manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful  
interference in which case the user will be required to correct the interference at  
his/her own expense.  
PS250 User Instructions  
 
1
 
Safety  
Warnings  
Safe installation  
Take care when lifting and transporting heavy objects.  
Do not overload the machine. Take care not to exceed the  
weighing capacity of the machine.  
Pluggable equipment must be installed near an easily  
accessible socket outlet. Permanently connected equipment  
must have a readily accessible disconnect device incorporated  
in the fixed wiring.  
For your protection all mains (110V or 230V) equipment used  
out of doors or in wet or damp conditions should be supplied  
from a correctly fused source and protected by an approved  
RCD to BS7071 or BS7288 or BS4293.  
The mains lead must be connected to a supply outlet with a  
protective earth contact. The electrical supply at the socket  
outlet must provide overcurrent protection of an appropriate  
rating.  
IF IN DOUBT SEEK ADVICE FROM A QUALIFIED  
ELECTRICIAN.  
Safe use  
To avoid the possibility of electric shock or damage to the  
machine, always switch off the machine and isolate from the  
power supply before carrying out any routine maintenance.  
Cleaning the machine  
CAUTION: Harsh abrasives, solvents, scouring cleaners and  
alkaline cleaning solutions, such as washing soda, should not  
be used especially on the display windows. Under no  
circumstances should you attempt to wipe the inside of the  
machine.  
PS250 User Instructions  
 
3
         
The outside of standard products may be wiped down with a  
clean cloth moistened with water containing a small amount of  
washing up liquid or disinfectant  
EMC compliance  
The following warning may be applicable to your machine.  
WARNING:This is a class A product. In a domestic environment  
this product may cause radio interference in which case the  
user may be required to take adequate measures.  
4
PS250 User Instructions  
 
 
1 About your machine  
1
About your machine  
1.1  
Description  
The PS250 is a self contained portable platform scale with a  
remote display. The platform is constructed of mild steel; it  
has four adjustable feet for levelling and a non-slip mat for the  
platform. A bracket and fixings are supplied for desk or wall  
mounting the indicator head. For best results, always install  
the platform on a hard, flat, level surface.  
A stainless steel platform version is available.  
1.2  
Display  
SALTER  
Brecknell  
ON-OFF  
Net  
ZERO  
UNITS  
kg/x  
HOLD  
TARE  
0
è0ç  
T
kg  
888888.8 lb oz  
Low  
250kg x 0.1kg/550lb x 0.2lb  
PS250  
Stable  
Minus  
Net weight  
net  
Hold weight  
Centre of zero  
Low battery  
weighing mode  
weighing mode  
lb  
0
kg  
Low  
1.3  
Key functions  
ZERO  
Zero/ON/OFF key. Switches the scale on or off.  
è0ç  
TARE  
T
Tare key.  
Applies a tare value  
PS250 User Instructions  
 
5
       
1 About your machine  
UNITS  
kg/x  
Units key  
Selects weighing units  
HOLD  
Hold key  
Retains average weight display.  
1.4  
1.5  
Error codes  
Err  
Overload  
ErrL  
ErrE  
Below zero  
EEprom error  
Low battery warning  
Low  
Specification  
Capacity/resolution  
250kg x 0.1kg  
550lb x 0.2lb  
Height 25mm  
7 segment LCD  
5º C to 35º C  
22kg  
Display  
Operating temperature  
Weight  
Dimensions  
Platform  
900mm x 550mm x 50mm  
270mm x 90mm x 45mm  
Display head  
Power supply  
6 x 1.2V metal hydride  
rechargeable batteries  
Recharge adaptor  
1 x 100V-240V AC/13V DC  
6
PS250 User Instructions  
 
   
1 About your machine  
1.6  
Power supply  
The indicator head contains six metal hydride re-chargeable  
batteries. The low battery indicator Low is displayed when the  
battery power is insufficient to power the scale.  
Recharging the batteries  
Insert the AC re-charger adapter into the socket on the  
indicator head to recharge the batteries.  
Recharging time is approximately 14 hours.  
Fully charged batteries should give approximately eight hours  
of continuous use.  
CAUTION: Always connect the AC adaptor to the indicator  
head before connecting to the mains power supply.  
Disconnect from the mains power supply before disconnecting  
the adaptor from the indicator head.  
AC adaptor  
The 100V/240V recharge adaptor supplied with the PS250 is  
provided with four convertion connectors:  
2 pin European  
3 pin UK  
2 pin USA  
2 pin Australia  
PS250 User Instructions  
 
7
 
2 Weighing  
2
Weighing  
For best results, always weigh on a hard flat and level surface.  
The platform has four adjustable feet for levelling.  
ZERO  
è0ç  
Press  
to switch on the scale. The display will show  
ꢀꢀꢀꢀthen go to weighing mode. If the display does not show  
ZERO  
è0ç  
ꢂꢃꢂ or press  
.
ZERO  
è0ç  
To switch off the scale, press and hold  
.
1. If necesssary, zero the scale.  
ZERO  
è0ç  
0
kg  
0.0  
15.3  
2.  
kg  
Using tares  
3.  
ZERO  
è0ç  
0
kg  
0.0  
8
PS250 User Instructions  
 
 
2 Weighing  
4.  
kg  
15.3  
net  
TARE  
T
0
kg  
0.0  
5.1  
5.  
net  
kg  
6. To cancel a tare  
net  
kg  
15.3  
0.0  
ZERO  
è0ç  
0
kg  
Weighing units  
UNITS  
kg/x  
Press  
to toggle between kg, lb and oz.  
PS250 User Instructions  
9
 
2 Weighing  
2.1  
Hold function  
This function enables you to weigh oversized objects that may  
obscure the display. The system calculates an average  
weight reading and displays this weight value. This makes  
the hold function ideal for weighing animals that may be  
moving around on the platform.  
1.  
0
kg  
0.0  
2.  
HOLD  
0
kg  
0.0  
3.  
kg  
16.3  
When the annunciator stops flashing, the weight is  
displayed and remains even when the load is removed.  
kg  
16.3  
10  
PS250 User Instructions  
 
 
2 Weighing  
4. To cancel the hold:  
HOLD  
0
kg  
0.0  
PS250 User Instructions  
 
11  
3 Setup mode  
3
Setup mode  
3.1  
Function setup  
In setup mode you can configure the following functions:  
weighing unit  
auto shut-off  
calibration weight  
Auto shut-off switches off the scale if no activity is sensed  
during the period set. The time values are in seconds. To  
disable auto shut-off, select 2)).  
Calibration weight allows you to select full load, 0.5 load or  
0.25 load of the machine capacity for calibration. The table  
lists the actual weight value you should use.  
1/2 load  
1/4 load  
Weighing Full load  
units  
kg  
200 kg  
500 lb  
100 kg  
200 lb  
50 kg  
lb  
100 lb  
Calibration weights  
12  
PS250 User Instructions  
 
     
3 Setup mode  
Set  
CAL  
Unit  
A.OFF  
120  
CAP  
180  
divS  
300  
GrAv  
End  
ꢄꢅꢆ  
240  
OFF  
lb  
kg  
oz  
ON  
OFF ON  
OFF ON  
OFF  
Setup menu  
Navigating the setup menu  
TARE  
1. Press and hold  
until display shows 6(7  
T
(approximately three seconds).  
TARE  
2. Release  
, display shows 81,7.  
T
UNITS  
kg/x  
3. Press  
require.  
to move across to the option or value you  
HOLD  
4. Press  
to select an option and save.  
To exit the setup menu and save your changes:  
UNITS  
kg/x  
Press  
until you see End.  
HOLD  
Press  
mode.  
to save your changes and return to weighing  
PS250 User Instructions  
 
13  
3 Setup mode  
3.2  
Calibration  
1. In setup mode, select &$/ꢁand then select whether you you  
want to use 1/2, full or 1/4 load for calibration (see  
Calibration weightson page 12). The example shown in  
these instructions uses kg weight units and 1/2 load. Save  
your selection and then switch off the scale.  
1.  
Hold  
ZERO  
è0ç  
At the same time  
UNITS  
kg/x  
x 3  
lb  
4076  
Display shows zero count value.  
2.  
TARE  
T
0
lb  
0
14  
PS250 User Instructions  
 
 
3 Setup mode  
3.  
to select alternate units  
0
UNITS  
kg/x  
lb  
0
0
kg  
0
4.  
5.  
100kg  
kg  
7978  
TARE  
T
kg  
cal lb oz  
kg  
100.0  
PS250 User Instructions  
 
15  
 
 
P.O. Box 9533, Smethwick,  
West Midlands, B66 2TE  
Tel UK: 0870 444 6132 Fax UK: 0870 010 2241  
Email:  
Email:  
Salter Brecknell Weighing,  
3620 Central Avenue NE, Minneapolis,  
MN 55418, USA.  
Tel: 612 781 4211 Fax: 612 781 4320  
 

Radio Shack Speaker 40 293 User Guide
Radio Shack Telephone Accessories CE 135 User Guide
RedMax Chainsaw GZ7000 User Guide
ResMed Oxygen Equipment VPAP III ST A User Guide
Ricoh Digital Camera Caplio rr1 User Guide
Runco Home Theater System Home Theater Projection System User Guide
Samsung Flat Panel Television LA32A650A1R User Guide
Samsung Tablet Tab4 User Guide
Savin Printer 3150eDNP User Guide
Seiko Watch V110 User Guide