Roper Dishwasher RUD6050R User Guide

Undercounter Dishwasher  
PRODUCT MODEL NUMBERS  
OVERALL DIMENSIONS  
RUD6050R  
24" (61 cm)*  
23-7/8" (60.6 cm)  
Electrical: 120-volt, 60 Hz, AC-only, 15 or  
20 amp. electrical supply. Use copper wire only. A  
time-delay fuse or circuit breaker and separate  
circuit is recommended.  
33-7/8"  
(86 cm) min.  
Water: A hot water line with 20-120 psi  
(138-862 kPa) water pressure. Water temperature  
must be 120°F (49°C) at dishwasher. Use 3/8" O.D.  
copper tubing with compression fitting (1/2"  
minimum plastic tubing is optional but not  
recommended). Use a 90° elbow with 3/8" N.P.T.  
external pipe threads on one end to connect to  
water inlet valve. Do not solder within 6" (15.2 cm)  
from water inlet valve.  
* to front of  
door frame  
20-3/4"  
(52.7 cm)  
CABINET OPENING DIMENSIONS  
Drain: Use the new drain hose supplied with your  
dishwasher. If this is not suitable, use a new drain  
hose with a maximum length of 12 feet (3.7 m)  
that meets all current AHAM/IAPMO test  
standards, is resistant to heat and detergent, and  
fits the drain connector of the dishwasher. Must  
have a high drain loop 20 inches (50.8 cm) above  
the subfloor or floor. Connect drain hose to waste  
tee or disposer inlet above drain trap in house  
plumbing and 20 inches (50.8 cm) minimum  
above the floor. An air gap must be used if the  
drain hose is connected to house plumbing lower  
than 20 inches (50.8 cm) above subfloor or floor.  
Use 1/2" minimum I.D. drain line fittings.  
24" (61 cm)**  
*Measured from the lowest point on the  
underside of countertop. May be reduced  
to 33-7/8" (86 cm) by removing wheels  
from dishwasher.  
**Minimum, measured from narrowest point  
of opening.  
24" (61 cm)  
34" (86.4 cm) min.*  
Corner location: Requires a 2" (5.1 cm)  
minimum clearance between the side of the  
dishwasher door and wall or cabinet.  
6"(15.2 cm)  
4" (10.2 cm)  
6"(15.2 cm)  
A side panel kit is available from your dealer for  
installing your dishwasher at end of cabinet.  
4"  
4"  
(10.2 cm)  
(10.2 cm)  
Do not install dishwasher over carpeted floor.  
10"  
2-1/2"  
(6.4 cm)  
2-1/2"  
(25.4 cm)  
(6.4 cm)  
2"  
(5.1 cm)  
5" (12.7 cm)  
5" (12.7 cm)  
2"  
(5.1 cm)  
Water line entering through the  
left side of opening in shaded  
areas makes connection easier.  
Minimum 1/2" (12,7 mm) hole.  
Drain hose and power supply line entering through the right  
side of opening in shaded areas makes connection easier.  
Drain hose size: 1-1/2" (3.8 cm)  
Power supply line hole-direct wired: 3/4" (1.9 cm)  
Power supply line hole-with plug: 1-1/2" (3.8 cm)  
CUSTOM FRONT PANEL DIMENSIONS (Framed)  
Cut door panel to clear access panel when  
These panels fit only models with frames around the door and access panels.  
door is in open position .  
7/32"  
(5.6 mm)  
door closed  
door panel (front view)  
side view  
door pivot  
NOTE: Access panel is wider than door panel.  
door panel  
(side view)  
3/8"  
(9.5 mm)  
door opened  
23 5/16" (59.2 cm)  
18 21/32"  
(47.4 cm)  
access panel  
(front view)  
access panel  
1"  
4 7/16"  
(11.3 cm)  
(25.4 mm)  
7/32" (5.6 mm) thick  
All edges routed to 7/32" (5.6 mm) thickness.  
22 31/32"  
(58.3 cm)  
top view  
7/32"  
(5.6 mm)  
1/4"  
(6.4 mm) min.  
access panel frame  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 8535436  
02-02-06  
 

Quantum Network Card SDLT 600A User Guide
Radio Shack Scanner Race Scanner User Guide
Radio Shack Speaker 40 210 User Guide
Razor Mobility Scooter EN_130402 User Guide
Remington Electric Shaver R 9500 User Guide
Samsung DVR DVD VR355 User Guide
Samsung Flat Panel Television 400EX User Guide
Samsung Projector SP P410M User Guide
Sanyo Air Conditioner CH0921 User Guide
Schumacher Battery Charger MKC 10P User Guide