Reliable Network Router DL 04 User Guide

Rev. 1.70  
Serial Number:___________________  
Model DL-04  
DATA-LOGGER  
WIRELINE DATA-LOGGER  
USER MANUAL  
© 1996-2008, Reliable Scale Corporation  
Reliable Scale Corporation  
520 Moraine Road N.E.  
Calgary, Alberta, Canada  
Tel:1-800-419-1189  
(403) 272-8784  
Fax: (403) 273-9818  
 
Reliable Scale Corporation  
2. Capabilities  
The Model DL-04 DATA-LOGGER is a versatile tool designed to record line  
load, line speed and tool depth on Wireline trucks.  
This new technology offers secure data recovery and reduces chances of operator  
error and improves record keeping. The result is an improved profit picture.  
The DL-04 stores data accurately without interfering with the operator’s normal  
activities.  
The DL-04 monitors the truck’s digital weight indicator, depth meter and line speed  
meter as often as every 2 seconds and stores the information securely in memory.  
This allows the manager to review very closely the details of each job.  
2.1 Features  
Lists job description, operator ID, job date  
Each record includes record number, line load, line speed, depth, and time of  
day  
Stores up to 113,825 records (over 63 hours of continuous recording at 2 second  
log intervals)  
Reads data at 2 second to 99 second intervals  
Support for 115,200 bps serial transfers  
XON/XOFF flow control for serial transfers  
Page 3 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
3. Physical Layout  
12 Volt DC Power Input - 4 pin male military style connector (P/N: PT02A8-  
4P).  
LCD Screen - displays instruction and status messages to the operator.  
Alphanumeric Keys - operator keys in information.  
Data Control Keys - for Entering and Editing data.  
RS-232 Ports - 4 pin female military style connectors (P/N: PT02A8-4S) to  
connect devices to the DL-04. Example: Digital Scale, Personal Computer, Line  
speed indicator.  
Arrow Keys - to scroll through menus and stored information.  
Function Keys - to issue commands; keys are assigned different functions as  
listed on the LCD screen.  
Power Key - to turn the DL-04 on and off.  
Page 4 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
4. Basic Operation  
1. Press the ON/OFF key until text appears.  
RELIABLE SCALE  
DL-04 DATA-LOGGER  
S/N: 9903148  
Screen shows the serial number and the  
software version.  
Version 1.60  
RELIABLE SCALE  
DL-04 DATA-LOGGER  
1999-03-29 14:09:23  
F1: Continue  
The next screen shows date & time for  
operator verification with local time  
zones.  
2. Press F1 to continue.  
MAIN MENU  
1 Log Data  
2 Resume Logging  
Screen shows the first two options  
available from the Main Menu.  
Select #  
more:T  
3. Use the UP and DOWN arrow keys to  
scroll through all the options.  
MAIN MENU  
3 Delete Data  
4 View Data  
Select #  
more:S  
MAIN MENU  
5 Plot Chart  
6 Print Data  
Select #  
more:S  
4. Select the option you wish to use.  
Example: 1 Log Data  
Page 5 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
MAIN MENU  
1 Log Data  
2 Resume Logging  
Select # more:T  
5. When an process has been completed,  
the DL-04 will return to the Main Menu.  
Page 6 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
4.1 Log Data  
The chief function of the DL-04 is the Log Data process.  
The screen prompts the operator through the necessary steps, issuing  
instructions as required. Once the operator initiates a job, each record is  
saved automatically for future transfer and analysis.  
Once logging has begun, the screen is updated every log interval with  
the latest log information. This maintains a record of:  
Tool Depth with units  
Line Speed with units  
Entry Time  
Line Load with units  
Entry Number (max. 113,825)  
MAIN MENU  
1 Log Data  
2 Resume Logging  
1. From the Main Menu, select Log  
Data.  
Select #  
more:T  
Well Name:  
F2: Alpha  
Operator is prompted for required  
information starting with Well Name  
F4: Quit ENTR: Accept  
2. Key in the Well name.  
Example: K14 If letters are used press  
F2 to enter alpha mode  
Well Name:  
The screen will change slightly  
F2: Accept alpha  
f: Next position  
Page 7 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
3. Press the number and arrow  
keys to scroll through the  
letters shown at the top of the  
keys.  
Well Name:  
K  
F2: Alpha  
4. Use F2 to exit alpha mode and the  
screen will return to normal  
F4: Quit ENTR: Accept  
5. Input numbers normally  
Well Number:  
F2: Alpha  
6. Well Number is next. Follow the  
same procedure as for Well Name.  
F4: Quit ENTR: Accept  
7. Key in Well Number.  
Example: 45  
Well Number:  
45„  
F2: Alpha  
F4: Quit ENTR: Accept  
Wireline Job Type:  
F2: Alpha  
8. Wireline Job Type is next. Follow  
the same procedure as for Well  
Name.  
F4: Quit ENTR: Accept  
9. Key in Wireline Job Type.  
Example: COMPLETION  
Wireline Job Type:  
COMPLETION„  
F2: Alpha  
F4: Quit ENTR: Accept  
Page 8 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
Job Operator:  
F2: Alpha  
10. Job Operator is next. Follow the  
same procedure as for Well Name.  
F4: Quit ENTR: Accept  
11. Key in Job Operator.  
Example: 58  
Job Operator:  
58„  
F2: Alpha  
F4: Quit ENTR: Accept  
Log Interval(s): „  
Log Interval is next. Intervals from 2  
seconds to 99 seconds between  
records are available.  
Min: 2s Max: 99s  
F4: Quit ENTR: Accept  
12. Key in the Interval.  
Example: 2  
LOGGING. . .  
The DL-04 begins reading data every  
256.42m  
10:23:10  
F4: Quit  
122m/m  
4990kg  
000085  
2 seconds.  
13. Logging can be interrupted by  
pressing F4.  
Page 9 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
4.2 Resume Logging  
If a job has been interrupted for some reason, it can be resumed using  
the Resume Logging process. Only the last job in memory can be  
resumed. If there are no jobs in memory, this process cannot be used.  
MAIN MENU  
1 Log Data  
2 Resume Logging  
1. From the Main Menu, select Resume  
Logging.  
Select #  
more:T  
LOGGING. . .  
The operator is asked to confirm the  
resume operation.  
Resume Job # 3?  
F2: Confirm  
F4: Cancel  
2. Press F2 to confirm resumption.  
Resuming Job #: 3  
LOGGING. . .  
3. The DL-04 Resumes logging  
256.42m  
10:23:10  
F4: Quit  
122m/m  
4990kg  
000085  
4. Logging can be interrupted by  
pressing F4.  
Page 10 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
4.3 Delete Data  
After the records have been plotted (see section 4.5 on page 14) or  
transferred to a computer (see section 4.6 on page 16), clear the DL-04  
memory using the Delete Records option. Jobs should be deleted after  
each day to make room for new ones and to eliminate confusion.  
MAIN MENU  
2 Resume Logging  
3 Delete Data  
1. From the Main Menu, select Delete  
Data.  
Select #  
more:T  
F2: Confirm  
Delete data  
F4: Cancel  
Delete data  
The operator is asked to confirm the  
delete operation.  
2. Press F2 to Delete Records.  
Enter password:„  
A password is required. The factory  
default password is 1234. See section  
5.4 on page 31 to change password.  
3. Enter the  
password.  
Enter password:****„  
When the password is entered, *'s are  
displayed for security.  
Page 11 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
Deleting data  
Data DELETED  
If a valid password has been entered,  
the records are deleted and the status is  
displayed on the screen.  
Page 12 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
4.4 View Job Information  
Job information in the DL-04 memory can be viewed on screen without  
transferring or deleting it.  
MAIN MENU  
3 Delete Data  
4 View Job Info.  
1. From the Main Menu, select View Job  
Info.  
Select #  
more:T  
VIEW JOBS  
Job to View? (3)  
If there is more than one job in memory,  
the user will be prompted for the job  
number.  
F4: Quit  
2. Enter job number to view.  
VIEW JOBS  
Job # 3  
3. The selected job information is  
displayed. Use the UP and DOWN arrow  
keys to scroll through the information.  
Job Description:  
F4: Quit  
more:T  
4. To quit viewing, press F4.  
Page 13 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
4.5 Plot Chart  
Data saved in the DL-04 can be transferred to a printer or computer in  
the form of a chart (Line Pull and Depth vs. Time). Connect the DL-04  
to the printer or computer with the proper cables & hardware. Be sure  
the printer/computer is ready to receive the data. The default serial port  
configuration for the DL-04 is 9600 baud, 8 data bits, no parity, 1 stop  
bit.  
Plotting a job does not remove it from the DL-04’s memory. Records  
are stored permanently in memory and can only be removed by using  
the Delete Data option (see section 4.3, on page 11). Data transfer can  
be done as many times as desired before deletion.  
Note: The DL-04 has been configured for use with an Epson FX-880  
printer with an RS-232 serial interface. Other compatible printers should  
function, but proper operation is not guaranteed.  
MAIN MENU  
5 Plot Chart  
6 Print Data  
1. From the Main Menu, select Plot Chart.  
Select #  
more:T  
PLOT CHART  
Job to Print? (3)  
If there is more than one job in memory,  
the user will be prompted for the job  
number.  
F4: Quit  
2. Enter job number to plot.  
PLOT CHART  
Plotting record: 457  
3. During data transfer, the number of the  
entry currently being plotted is  
displayed.  
F4: Quit  
Page 14 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
4. To quit printing, press F4.  
Page 15 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
4.6 Print Data  
Data saved in the DL-04 must be transferred to a host computer for  
historical storage and analysis. Connect the DL-04 to the computer with  
the proper cables & hardware. Be sure your computer is ready to  
receive the records. The default serial port configuration for the DL-04 is  
9600 baud, 8 data bits, no parity, 1 stop bit. A standard terminal  
program such as Procomm or HyperTerminal can be used for this  
procedure (see your terminal program manual for details).  
Transferring jobs to computer does not remove them from the DL-04’s  
memory. Records are stored permanently in memory and can only be  
removed by using the Delete Data option (see section 4.3, on page 11).  
Data transfer can be done as many times as desired before deletion.  
MAIN MENU  
6 Plot Chart  
5 Print Data  
1. From the Main Menu, select Print Data.  
Select #  
more:T  
PRINT DATA  
Job TO Print? (3)  
If there is more than one job in memory,  
the user will be prompted for the job  
number.  
F4: Quit  
2. Enter job number to print.  
PRINT DATA  
Printing record: 457  
3. During data transfer, the number of the  
entry currently being printed is  
displayed.  
F4: Quit  
Page 16 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
4. To quit printing, press F4.  
Page 17 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
5. Configuration  
Some operating features of the DL-04 can be modified to suit the  
equipment being used. Other parameters such as the date and time need  
to be set in order to make accurate logs. All parameters are set from the  
Configuration Menu.  
MAIN MENU  
6 Pint Data  
7 Configuration  
1. From the Main Menu, select  
Configuration.  
Select #  
more:S  
CONFIGURATION MENU  
1 Set Date  
2. Screen shows first two items of the  
Configuration Menu. Use the UP and  
DOWN arrow keys to scroll through all  
the options.  
2 Set Time  
Select #  
more:S  
CONFIGURATION MENU  
3 Configure Ports  
4 Set Depth Units  
Select #  
more:S  
CONFIGURATION MENU  
6 Set Password  
7 Exit Configuration  
3. To return to the Main Menu, select Exit  
Configuration.  
Select #  
more:S  
Page 18 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
5.1 Set Date  
The current date can be seen when the DL-04 is turned on. It is  
important that this be set correctly in order to provide accurate log  
information. If the date needs to be changed, it is done using the Set  
Date process from the Configuration Menu.  
CONFUGIRATION MENU  
1 Set Date  
2 Set Time  
1. From the Configuration Menu, select  
Set Date.  
Select #  
more:T  
SET DATE  
Enter year:  
2. Key in the year. Use four digits.  
Example: 1999  
F4: Quit  
SET DATE  
Enter month:  
3. Key in the month. (1 to 12)  
Example: 2  
F4: Quit  
SET DATE  
Enter day:  
4. Key in the day. (1 to 31)  
Example: 12  
F4: Quit  
Page 19 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
SET DATE  
The new date is displayed before  
returning to the Configuration Menu.  
Date set to:  
1999-02-12  
5. To quit, press F4.  
Page 20 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
5.2 Set Time  
The current time can be seen when the DL-04 is turned on. It is  
important that this be set correctly in order to provide accurate log  
information. If the time needs to be changed, it is done using the Set  
Time process from the Configuration Menu.  
CONFUGIRATION MENU  
1 Set Date  
2 Set Time  
1. From the Configuration Menu, select  
Set Time.  
Select #  
more:T  
SET TIME  
Enter hour(24):  
2. Key in the hour. (0 to 23)  
Example: 14  
F4: Quit  
SET TIME  
Enter minute:  
F4: Quit  
3. Key in the minute. (0 to 59)  
Example: 25  
SET TIME  
Enter second:  
F4: Quit  
4. Key in the second. (0 to 59)  
Example: 50  
Page 21 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
SET TIME  
The new time is displayed before  
returning to the Configuration Menu.  
Time set to:  
14:25:50  
5. To quit, press F4.  
Page 22 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
5.3 Configure Ports  
The ports on the DL-04 can be assigned to different devices to suit  
individual applications. It is recommended however, that the default  
port settings be used. They are:  
Port 1 - Computer/Printer  
Port 2 - Counter  
Port 3 - Weight Indicator  
CONFIGURATION MENU  
2 Set Time  
3 Configure Ports  
1. From the Configuration Menu, select  
Configure Ports.  
Select #  
more:S  
PORT CONFIG MENU  
1 Show Port Function  
2 Set Port Function  
2. Screen shows first items of the Port  
Config Menu. Use the UP and DOWN  
arrow keys to scroll through all the  
options.  
Select #  
more:S  
PORT CONFIG MENU  
3 Set Port Speed  
4 Set Port Format  
Select #  
more:S  
CONFIGURATION MENU  
5 Port Test  
6 Exit Port Config  
3. To return to the Configuration Menu,  
select Exit Port Config.  
Select #  
more:S  
Page 23 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
5.3.1 Show Port Function  
The current port assignments can be seen by using the Show Port  
Function option in the Port Config Menu. This can be a useful  
troubleshooting tool if device communications problems arise.  
PORT CONFIG MENU  
1 Show Port Function  
2 Set Port Function  
1. From the Port Config Menu, select  
Show Port Function  
Select #  
more:S  
PORT FUNCTIONS  
PC Port:  
2. Screen shows first Port Functions. Use  
the UP and DOWN arrow keys to scroll  
through the list.  
1
2
Counter Port:  
F4: Quit  
more:S  
PORT FUNCTIONS  
Weight Port  
3
1
Printer Port  
F4: Quit  
more:S  
3. To quit, press F4.  
Page 24 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
5.3.2 Set Port Function  
The current port assignments can be changed using the Set Port  
Function option in the Port Config Menu. It is recommended that the  
default port assignments be used.  
PORT CONFIG MENU  
1 Show Port Function  
2 Set Port Function  
1. From the Port Config Menu, select Set  
Port Function  
Select #  
more:S  
SET PORT FUNCTION  
Enter port number:  
2. Key in the port to be changed.  
Example: 1  
F4: Quit  
more:S  
Select Function:  
3. Select the function.  
1:PC  
2:Printer  
Example: 1:PC  
3:Scale 4:Counter  
SET PORT FUNCTION  
Port: 1  
Function: PC  
4. To quit, press F4.  
Page 25 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
5.3.3 Set Port Speed  
Using the Set Port Speed option, the port baud rates can be set to  
accommodate the needs of the device connected to it. It is important  
that this setting is correct for proper device interfacing.  
Supported Baud Rates  
1200  
2400  
4800  
9600  
19,200  
38,400  
115,200  
PORT CONFIG MENU  
3 Set Port Speed  
4 Set Port Format  
1. From the Port Config Menu, select Set  
Port Speed.  
Select #  
more:S  
SET PORT SPEED  
Enter port number:  
2. Key in the port to be changed.  
Example: 1  
F4: Quit  
more:S  
SET PORT SPEED  
Enter port 1 speed:  
3. Key in the baud rate.  
Example: 9600  
F4: Quit  
more:S  
Page 26 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
SET PORT FUNCTION  
Port: 1  
Speed: 9600 baud  
4. To quit, press F4.  
Page 27 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
5.3.4 Set Port Format  
Using the Set Port Format option, the word length and parity  
parameters for a port can be set to accommodate the needs of the  
device connected to it. It is important that these settings are correct for  
proper device interfacing.  
Supported Word Lengths  
7
8
PORT CONFIG MENU  
3 Set Port Speed  
4 Set Port Format  
1. From the Port Config Menu, select  
Show Port Function  
Select #  
more:S  
SET PORT FORMAT  
Enter port number:  
2. Key in the port to be changed.  
Example: 1  
F4: Quit  
more:S  
SET PORT FORMAT  
Enter word length:  
3. Key in the word length.  
Example: 8  
F4: Quit  
more:S  
Page 28 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
Select Parity:  
1:Even 2:Odd  
3:Mark 4:Space  
5:None  
4. Choose the parity setting.  
Example: 5:None  
SET PORT FORMAT  
Port: 1  
Format: 8,N,1  
5. To quit, press F4.  
Page 29 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
5.3.5 Port Test  
Proper port operation can be tested using the Test Port Function option  
in the Port Config Menu. This function should not be used when  
connected to the measurement devices as they can be damaged. This  
can be a useful troubleshooting tool if device communications  
problems arise and should only by used by trained personnel. A test  
string will be transmitted by each port using its current settings.  
PORT CONFIG MENU  
5 Port Test  
6 Exit Port Config  
1. From the Port Config Menu, select Port  
Test  
Select #  
more:S  
Testing Ports.  
F4: Quit  
more:S  
2 To quit, press F4.  
Page 30 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
5.4 Set Depth Units  
As the Depth Counter does not provide unit information to the DL-04,  
the user must specify the depth and time units to used for logging.  
Configuration MENU  
3 Configure Ports  
4 Set Depth Units  
1. From the Configuration Menu, select  
Set Depth Units.  
Select #  
more:T  
SET UNITS  
Select Depth Units:  
1:meters 2:feet  
2. Key in the depth units.  
Example: 1:meters  
SET UNITS  
Select Depth Units:  
Depth Units: meters  
SET UNITS  
Select Time Units:  
1:minutes 2:seconds  
5. Key in the depth units.  
Example: 1:minutes  
SET UNITS  
Select Time Units:  
Time Units: minutes  
Page 31 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
5.5 Plot Delay  
In order to allow the printer to keep up with the data transfer, a time  
delay is used. After each line of the chart has been transferred, the DL-  
04 waits for a specific amount of time. This length of time is  
determined by the Plot Delay setting and is measured in milliseconds.  
CONFIGURATION MENU  
5 Plot Delay  
6 Set Password  
1. From the Configuration Menu, select  
Plot Delay.  
Select #  
more:S  
SET DELAY  
2. The current Plot Delay setting is  
displayed and the user in prompted for  
the new setting.  
Current Delay: 1100  
New Delay: „  
F4: Quit  
SET DELAY  
Current Delay: 1100  
New Delay: 1500„  
F4: Quit  
3. Key in the new Port Delay setting.  
Example: 1500mS  
SET DELAY  
Plot Delay: 1500mS  
4. To quit, press F4.  
Page 32 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
5.6 Set Password  
A password is required to delete data from the DL-04. If a password  
other than the factory default (1234) is desired, it can be changed using  
the Set Password process.  
Configuration MENU  
3 Configure Ports  
4 Set Password  
1. From the Configuration Menu, select  
Set Password.  
Select #  
more:T  
CHANGE PASSWORD  
Old Password:  
2. Key in the old password.  
F4: Quit  
When the password is entered, *'s are  
displayed for security.  
CHANGE PASSWORD  
New Password:  
F4: Quit  
4. Key in the new password.  
When the password is entered, *'s are  
displayed for security.  
CHANGE PASSWORD  
Confirm Password:  
F4: Quit  
5. Key in the new password again to  
confirm it.  
When the password is entered, *'s are  
displayed for security.  
CHANGE PASSWORD  
New Password Saved.  
F4: Quit  
Page 33 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
6. To quit, press F4.  
Page 34 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
6. Troubleshooting  
1. The DL-04 won’t turn on.  
Ensure that the power connector is properly plugged in and is supplying  
12VDC. Pin A of the power connector is positive, pin B is negative.  
2. When transferring data to the computer, nothing happens or else the data  
looks like garbage.  
Check the cable connections to the computer and make sure the terminal  
program is properly configured. The default is 9600 baud, 8 data bits, no  
parity, 1 stop bit.  
Page 35 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
7. Sample Chart  
The following is a sample chart produced by the DL-04.  
Reliable Scale Corporation  
DL-04 Wireline Data-Logger  
Log Reoprt  
Report Date: 1999-10-22  
Job#: 4  
Start Entry: 50  
Well Name: TEST WELL  
Well Number: 452  
Wireline Job Type: TEST  
Job Operator: JOHN SMITTH  
Job Date: 1999-10-22  
Start Time: 08:23:35  
End Time: 08:25:33  
Log Interval: 2s  
* = Line Pull  
0 lb = 0%  
5818 lb = 100% + = Depth  
50%  
0 m = 0%  
38.54 m = 100%  
100%  
0%  
25%  
75%  
|-----------------------------|-----------------------------|-----------------------------|-----------------------------|  
08:23:35|*+  
|
|
|
|
|
|
|
|
|
|
|
|
|+  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*
08:23:37| *+  
08:23:39|  
08:23:41|  
08:23:43|  
08:23:45|  
08:23:47|  
08:23:49|  
08:23:51|  
08:23:53|  
08:23:55|  
08:23:57|  
08:23:59|  
08:24:01|  
08:24:03|  
08:24:05|  
08:24:07|  
08:24:09|  
08:24:11|  
08:24:13|  
08:24:15|  
08:24:17|  
08:24:19|  
08:24:21|  
08:24:23|  
08:24:25|  
08:24:27|  
08:24:29|  
08:24:31|  
08:24:33|  
08:24:35|  
08:24:37|  
08:24:39|  
08:24:41|  
08:24:43|  
08:24:45|  
08:24:47|  
08:24:49|  
08:24:51|  
08:24:53|  
08:24:55|  
08:24:57|  
08:24:59|  
08:25:01|  
08:25:03|  
08:25:05|  
08:25:07|  
08:25:09|  
08:25:11|  
08:25:13|  
08:25:15|  
08:25:17|  
08:25:19|  
08:25:21|  
08:25:23|  
08:25:25|  
08:25:27|  
08:25:29|  
08:25:31|  
08:25:33|  
+*  
+ *  
+ *  
+ *  
+*  
|
|
|
|
|
|
|
|
|
|
*+  
*
|
|
+
*
|
|
*
+
|
|
*
*
+
*
|
|
+
|
|
*
|
|
+
|
|
*
+
|
|
*
+
|
|
+
|
|
*
+
|
|
*
+
|
|
* |  
+
|
|
*|  
*
|*  
+ |  
|
|+  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*|  
+
|
| *  
| *  
|
+
|
+
|
*
+ +  
|
|
*
*
+
|
|
+
|
|
*
+
|
|
*
+
|
|
*
*
+
|
|
+
|
|
*
+ |  
+|  
|
*
*
|
|+  
| +  
| +  
| +  
|
|
*
*
|
|
*
*
|
|
*
*
|+  
|
|
+
+
|
*
|
|
*
+
+
|
|
*
+
|
|
+
|
|
|*  
|
|
| *  
|
+
|
|
*
|
|
|
*
+
|
|
|
*
+ |  
|
|
*
+
|
|
*
| +  
|
|
*
|
+
*
|
|
*
|
+
|
|
*
|
+
|
|
*
|
+
|
|
|*  
|
+
|
|
+
* +  
+
|
|
|
|
|
|
|-----------------------------|-----------------------------|-----------------------------|-----------------------------|  
0%  
25%  
50%  
75%  
100%  
60 entries plotted  
Page 36 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
8. Sample Log  
The following is a sample log gathered by the DL-04. Each column has  
a fixed number of characters and is separated by a comma (,). The  
columns are organized as follows:  
1. Log entry  
2. Memory location  
3. Log time  
4. Line Load  
5. Line depth  
6. Line speed  
Job#: 1  
Job Date: 1999-02-25  
Log Interval: 2s  
Start Entry:  
1
Job Description: WELL01  
Job Operator: BILL  
1,  
2,  
1, 15:28:46,  
2, 15:28:48,  
3, 15:28:50,  
4, 15:28:52,  
5, 15:28:54,  
6, 15:28:56,  
7, 15:28:58,  
8, 15:29:00,  
9, 15:29:02,  
10, 15:29:04,  
11, 15:29:06,  
12, 15:29:08,  
13, 15:29:10,  
14, 15:29:12,  
15, 15:29:14,  
16, 15:29:16,  
17, 15:29:18,  
18, 15:29:20,  
19, 15:29:22,  
20, 15:29:24,  
21, 15:29:26,  
22, 15:29:28,  
23, 15:29:30,  
24, 15:29:32,  
25, 15:29:34,  
26, 15:29:36,  
27, 15:29:38,  
28, 15:29:40,  
5377kg, 200.00m,  
5376kg, 200.00m,  
5376kg, 200.48m,  
5376kg, 202.20m,  
5376kg, 204.15m,  
5376kg, 206.51m,  
5376kg, 208.77m,  
5376kg, 210.12m,  
5376kg, 212.24m,  
5376kg, 214.08m,  
5376kg, 216.15m,  
5376kg, 218.32m,  
5376kg, 220.61m,  
5376kg, 222.91m,  
5376kg, 224.43m,  
5376kg, 226.28m,  
5376kg, 227.32m,  
5376kg, 228.32m,  
5322kg, 229.02m,  
5322kg, 230.07m,  
5447kg, 230.69m,  
5449kg, 232.78m,  
5449kg, 234.64m,  
5449kg, 237.06m,  
5449kg, 238.57m,  
5449kg, 238.82m,  
5449kg, 238.87m,  
5449kg, 238.87m,  
0m/m  
0m/m  
3,  
33m/m  
49m/m  
68m/m  
65m/m  
61m/m  
65m/m  
54m/m  
50m/m  
48m/m  
56m/m  
71m/m  
71m/m  
66m/m  
37m/m  
37m/m  
25m/m  
26m/m  
26m/m  
41m/m  
53m/m  
71m/m  
68m/m  
22m/m  
6m/m  
4,  
5,  
6,  
7,  
8,  
9,  
10,  
11,  
12,  
13,  
14,  
15,  
16,  
17,  
18,  
19,  
20,  
21,  
22,  
23,  
24,  
25,  
26,  
27,  
28,  
1m/m  
0m/m  
28 records printed  
Page 37 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 
Reliable Scale Corporation  
9. Limited Warranty  
This warranty applies to all new equipment manufactured by RELIABLE SCALE  
CORPORATION except when otherwise specified in the Terms of Sale. Warranty is subject to  
the following terms and conditions:  
All new products are warranted for a period of twelve (12) months from the date of final sale  
to the end user (maximum 24 months from date of manufacture).  
RELIABLE SCALE CORPORATION shall at its option, repair or replace or refund the  
purchase price, within a reasonable period of time, after being notified of the alleged defect  
and after acknowledging that a defect does in fact exist.  
Warranty claims must be submitted in writing by mail, fax or email to RELIABLE SCALE  
CORPORATION within the warranty period.  
This warranty does not extend to any consequential damage of other equipment, loss of use,  
commercial or economic loss or inconvenience prior to or during the repair period.  
RELIABLE SCALE CORPORATION is not responsible for any damage or defects caused  
by misuse, negligence, neglect, modification, improper operation, improper maintenance, or  
repairs by any unauthorized persons.  
This is the sole warranty applicable to RELIABLE SCALE CORPORATION'S products, and  
no RELIABLE SCALE CORPORATION employee, agent or dealer has any authority to  
add to this warranty whatsoever.  
Products for warranty repair must be returned to the factory freight prepaid by the customer.  
RELIABLE SCALE CORPORATION is not liable for any cost related to removal,  
replacement, or shipping of the products or any other associated equipment.  
Batteries supplied in or with RELIABLE SCALE CORPORATION products are NOT covered  
by this warranty.  
Page 38 of 38  
Rev. 1.70  
Model DL-04 DATA-LOGGER  
User Manual  
 

RCA Clock Radio RC10 User Guide
RCA Microcassette Recorder RP5030 User Guide
RCA Projection Television P52955 User Guide
RIDGID Satellite Radio WGSW 24020 User Guide
Rosen Entertainment Systems GPS Receiver DS UN0910 User Guide
Ryobi Blower RY09460 User Guide
Samsung Answering Machine 7B User Guide
Samsung Refrigerator DA99 01278C User Guide
Schneider Electric Switch KVM1116P User Guide
Scientific Atlanta DVR 3250HDTM User Guide